    Dimensions 
    Body Diameter
    35mm
    Body Length (to seal face)
    43mm (5V input) - 48mm (Other inputs)
    Probe Length (from seal face)
    Measurement length + 58mm
    Target Tube Length
    Measurement length +30mm, ID 7.7mm, OD 9.45mm

     

    Travel

    any stroke from 5mm to 800mm (eg 305mm)

    Independant Linearity

    <±0.25% up to 450mm <±0.50% over 450mm at 20°C

    Temperature Coefficient

    <±0.01%/°C Gain & <±0.01%FS/°C Offset
    See Graph

    Resolution

    Infinite

    Noise

    <0.02% FSO

    Frequency Response

    >10KHz (-3dB);
    >300Hz (-3dB); 2 wire 4-20mA

     

    Output Signal and Output Load

    Output SignalOutput Load

    0.5 to 4.5 V dc ratiometric5K Ohms min

    0.5 to 4.5 V dc5K Ohms min

    ± 5V dc5K Ohms min

    ± 10V dc5K Ohms min

    0.5 to 9.5 V dc5K Ohms min

    4 to 20mA (2 wire)300 Ohms @ 24V

    4 to 20mA (3 wire sink)950 Ohms @ 24V

    4 to 20mA (3 wire source)300 Ohms Max

    Supply Current

    12 mA Typical 20 mA max. (Voltage Versions) 

     

    Temperature Limits

     

    Operating

    -40 to +125°C (5V input only)
    -20 to +85°C

    Storage

    -40 to +125°C

    EMC Performance

     

    Susceptibility

    EN 61000-6-2

    Radiated

    EN 61000-6-3

     

    Vibration

    IEC 68-2-6: 10g

    Shock

    IEC 68-2-29: 40 g

    MTBF

    350,000 hrs 40°C Gf

    Hydraulic Pressure

    350 Bar

    Sealing

    IP65(connector) / IP67(cable)

     

    Electrical Connections

    Screened 3 core cable or integral connector

    Target

    A non-magnetic target tube is supplied with the sensor. This can be eliminated if the piston rod is made from non-magnetic steel and is drilled to a specified tolerance.

    Dimensions

    Refer to drawings below.

    Outline

    Click for pdf 
    Request AutoCAD Drawing

    Typical Installation in Cylinder

    Click for pdf 
    Request AutoCAD Drawing

    Sealing Details

    Click for pdf 
    Request AutoCAD Drawing

    Target Details Fitting

    Click for pdf 
    Request AutoCAD Drawing
    DatasheetClick for pdf
    Installation SheetClick for pdf
      
T-Soft E-Ticaret Sistemleriyle Hazırlanmıştır.